Plan 01 — Overview Schematic

GRADE ENTRY MAIN SPACE SYSTEMS DECON / WET 6 000mm 4 000 01 — THE SENTINEL SECTION VIEW — NOT TO SCALE

Engineering Schematics

FLOOR PLAN &
SCHEMATICS

The Sentinel's compact footprint is its strength — efficiently engineered with no wasted space. Ideal for installation adjacent to an existing residence or as a standalone bolt-hole on rural property.

Floor Plan — Single Level · 6m × 4m · 24m²

BLAST DOOR DECON ANTEROOM BUNK / SLEEP MAIN LIVING KITCHEN / DINING / COMMS AIR / POWER FILTRATION · SYSTEMS WET ROOM 6 000 4 000 FLOOR PLAN — SCHEMATIC ONLY — NOT TO SCALE

Side Elevation — Entry Wall

FINISHED GRADE SHAFT REINFORCED CONCRETE — 300mm WALLS, 400mm ROOF SLAB DECON MAIN HABITATION 2.6m ELEVATION — NOT TO SCALE

Technical Specifications

FULL
SPECIFICATION

Plan No.01 — The Sentinel
ClassificationSolo & Couple Saferoom / Bolt Hole
Total Area24m²
Footprint6m × 4m
Levels1 underground level
Excavation DepthApprox. 3.2m below finished grade
Capacity1–2 persons
Autonomy30-day self-sufficient provision
ShellSteel-reinforced concrete, 300mm walls, 400mm roof slab
EntryBlast-rated steel door with decontamination anteroom
Air SystemNBC-rated HEPA + activated carbon filtration, positive pressure
PowerBattery bank + generator rough-in provision
Water2,000L storage with filtration provision
SleepingIntegrated bunk provision (2 berths)
Wet RoomCombined shower/WC with grey water provision
CertificationNZ CPEng-stamped; adaptable to local codes

License Package

WHAT'S
INCLUDED

Full dimensioned floor plans

CAD-ready drawings with all dimensions and structural notes

Structural engineering drawings

CPEng-stamped with foundation, wall, and roof specifications

Full materials schedule

Complete bill of quantities for tendering and procurement

MEP schematics

Mechanical, electrical, and plumbing schematic layouts

1-hour site adaptation consultation

Direct session with our lead engineer for your site

Worldwide build license

Right to construct one structure anywhere with your chosen contractor

NDA-protected delivery

All documents delivered under standard NDA

Pricing

Pricing provided upon enquiry. Every engagement begins privately.

Request Pricing & License

All enquiries held under NDA. Response within 48 hours.

Ready to Proceed

LICENSE THE SENTINEL

The essential bolt hole. Compact, certified, ready to build. Enquire to receive pricing and full documentation.